How to Select the Right VS1 Vacuum Circuit Breaker for Medium Voltage Projects

0
714

While the VS1 VCB series has become a standard product in the medium-voltage market, not all models are suitable for all applications. Engineers, EPC contractors, and switchgear manufacturers must evaluate electrical, mechanical, and environmental factors before choosing the correct configuration.

Below is a complete selection guide for the VS1 vacuum circuit breaker.

1. Rated Voltage and System Compatibility

Most VS1 breakers are used in 6kV–12kV power systems, but there are also 24kV versions for higher distribution levels. The breaker must match the system neutral grounding method — insulated, grounded through resistor, or solid-grounded.

2. Rated Current and Load Requirements

Load Type Typical VCB Rating
Standard feeder 630A / 1250A
Transformer feeder 1250A / 1600A
Motor load 1600A with high mechanical endurance
Bus coupler / incoming panel 2000A / 2500A / 3150A

Incorrect current selection causes overheating and accelerated contact wear.

3. Short-Circuit Breaking Capacity

VS1 models are available in 20kA, 25kA, and 31.5kA versions. The correct value depends on the fault level of the grid. For renewable/industrial hybrid networks, 31.5kA is recommended due to unpredictable inrush currents.

4. Mechanical Type: Fixed or Withdrawable?

Type Suitable For
Withdrawable Maintenance-critical systems (substation feeders)
Fixed Compact switchgear, RMU, or cost-sensitive installations

5. Mechanism Options

Spring mechanism – traditional, durable, easy to service
Permanent magnet mechanism (PM) – high-end, zero-maintenance, used in digital substations

6. Environmental Options

  • Anti-condensation heaters for humid areas

  • High-altitude derating version (≥ 3000m)

  • Sand/dust-proof design for desert and mining regions

  • Tropical climate corrosion protection coating

7. Certification and Testing Checklist

Before procurement, the VS1 breaker should include:

Document Required
Type test report (IEC / GB)
Routine test certificate
Factory FAT report
Electrical drawings and wiring diagrams
Spare parts list

8. Supplier Selection Factors

  • Does the manufacturer provide OEM/ODM customization?

  • Are spare parts guaranteed for 10+ years?

  • Is after-sales technical support available?

  • Can factory inspection or third-party witness testing be arranged?

البحث
الأقسام
إقرأ المزيد
أخرى
PA Pulley vs. Nylon Pulley: Comparing Durability, Efficiency, and Performance
When choosing the right material for pulleys in mechanical systems, it's essential to understand...
بواسطة huanengpulley 2025-09-17 05:25:57 0 3كيلو بايت
Health
Best Doctor for Robotic Surgery in Guwahati: Advanced Care with Precision and Expertise | GI Surgery
In today’s world of advanced medical technology, many patients are searching for better,...
بواسطة gilapsurgery 2025-09-26 09:07:25 0 2كيلو بايت
Shopping
Why ZN63 (VS1) Vacuum Circuit Breaker Is the Preferred Choice for 12kV Systems
As the demand for safe and efficient medium-voltage control increases, the ZN63 vacuum circuit...
بواسطة ttstt 2025-11-05 06:24:57 0 740
Shopping
從iqos到ILIA,再到SHAXIAO,探索電子煙的無限可能
在電子煙市場日益繁榮的今天,iqos...
بواسطة pertend 2024-12-30 06:53:29 0 7كيلو بايت
أخرى
Securing Spaces: Trends Shaping the Global Door Security Bar Market
According to a new report published by Introspective Market Research, titled, "Door Security Bar...
بواسطة amitpatil 2025-11-03 05:18:30 0 754
iS Wao https://iswao.com